Super fine tuning button.
Large size of the fine adjustment button, the threshold adjustment is more convenient.
Large display + status indicator.
Connection mode: lead wire.
Output mode: NPN output. Detection methods: the firing pattern.
Detection range: 300mm.
Usage: slender type,
Small thin space probe;
Interference prevention function with close installationSize: 48 x 48mm E5EC-TQX4DSM-060 .
Control output 1: relay output
E5EC-TQX4DSM-060
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: - E5EC-TQX4DSM-060 .
Transfer output: have.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications E5EC-TQX4DSM-060 .
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. 2M E32-T10V amplifier flange
Connecting optical fiberPower supply voltage: 5 to 12 VDC.
Output configuration: Voltage output.
Output phases: Phases A, B, and Z.
Resolution (pulses/rotation): 100, 200, 360, 500.
Compact Encoder with External.
Diameter of 25 mm.
Incremental model.
External diameter of 25 mm.
Resolution of up to 500 ppr. Slit width: 0.5 mm dia.
Installation procedure: Plug-in type.
Applicable type: E3Z-T@@. Appearance: Standard.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON.
Complete lineuup including seven different shapes E5EC-TQX4DSM-060 Communications Manual.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations E5EC-TQX4DSM-060 Communications Manual.
Connector with lock that mates with commercially available,
connectors.