Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: - EJ1N-TC2B-QNHB.
Transfer output: output (using control output).
Communication: RS-232C.
New program type
EJ1N-TC2B-QNHB
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms EJ1N-TC2B-QNHB.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output EJ1N-TC2B-QNHB.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Appearance: 4 dia.
Sensing distance: 3 mm.
Connecting method: M8 Connector Models.
Cable specifications: --.
Operation mode: Nc.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: PNP output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Size: 96 x 96mm.
Control output 1: voltage.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed samplinng to achieve 50ms EJ1N-TC2B-QNHB.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion EJ1N-TC2B-QNHB.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.