Safety outputs: --.
Safety standstill detection output: 3.
Auxiliary output: 2.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Sensor-less Monitoring of Standstill for,
Machines with Long Inertia.
Standstill is monitored by the motor''s back electromotive force (BEMF) signal G3ZA-8A403-FLK-UTU REFERENCE MANUAL.
Features a "Standard Configuration", allowing immediate use,
without sensitivity adjustment
G3ZA-8A403-FLK-UTU
"User Configuration" also available for fine-tuning of sensitivity.
Detailed LED indications enable easy fault diagnosis.
Safety Category 4 (EN954-1), PLe(ISO13849-1),
SIL 3 (IEC/EN 62061) certified. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 G3ZA-8A403-FLK-UTU REFERENCE MANUAL.
Rated input voltage: 4 to 24 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Socket type, same size as LY Power Relays.
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix) G3ZA-8A403-FLK-UTU REFERENCE MANUAL. Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 100V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action dissplay lamp G3ZA-8A403-FLK-UTU Manual.
Output rated voltage: AC100 3A ~ 240V.
Input rated voltage: DC5 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, tthe color of each module to distinguish G3ZA-8A403-FLK-UTU Manual.
You can confirm the action of SSR by using the action display light.
Between input and output voltage 4000V.