Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 3 A at 4 to 48 VDC (See note 2.).
Rated input voltage: 5 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) G9SX-LM224-F10-RT Manual.
Socket type, same size as MY Power Relays
G9SX-LM224-F10-RT
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min. (between each in,
put terminal and the V terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the V terminal).
OFF current: 1 G9SX-LM224-F10-RT Manual. 0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 16 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply G9SX-LM224-F10-RT Manual.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 150 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times OMRON CPU Unit Manual.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors OMRON CPU Unit Manual.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing OMRON CPU Unit Manual.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Number of elements: 2.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal G9SX-LM224-F10-RT USER'S MANUAL.
Overload Relays.
Certified for UL and CSA.
Mount with screws or to DIN tracks.
Compact monoblock construction ((W: 80 × H: 100 × D: 100 mm) G9SX-LM224-F10-RT Manual.
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series.