LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON H7CX-A4SD-N Manual H7CX-A4SD-N Communications Manual

OMRON H7CX-A4SD-N Manual H7CX-A4SD-N Communications Manual

Product model: H7CX-A4SD-N
Name: Digital Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 0.65MB
Operating method: Reversible (selectable with rotary DIP switch) between,
0 and the set value; Incrementing/decrementing A/D (command inputs);
Incrementing/decrementing B/E (individual inputs);
Incrementing/decrementing C/F (phase difference inputs).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch) H7CX-A4SD-N Communications Manual.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L) H7CX-A4SD-N
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: Yes/No (Selectable using DIP switch) H7CX-A4SD-N Communications Manual.
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 2 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking H7CX-A4SD-N Communications Manual. Type: H5CZ.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s,
1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min, 1 to 9999 min,
1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Inputs: Signal, Reset (NPN inputs).
Outputs: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and inputt circuits are isolated for safety and reliability H7CX-A4SD-N Manual.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,
the load H7CX-A4SD-N Manual.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.
Related products
OMRON
Multifunction Counter/Tachometer
H7CX-R-N Series
OMRON Multifunction Counter/Tachometer H7CX-R-N Series
Ultra-compact Counter Provides More, Complet
OMRON
Multifunction Counter/Tachometer
H7CX-R11WD1-N
OMRON Multifunction Counter/Tachometer H7CX-R11WD1-N
Type: H7CX-R Series. Classification: Tachome
OMRON
Multifunction Counter/Tachometer
H7CX-A114-N
OMRON Multifunction Counter/Tachometer H7CX-A114-N
Type: H7CX-A Series. Classification: Preset
OMRON
Multifunction Counter/Tachometer
H7CX-A11D1-N
OMRON Multifunction Counter/Tachometer H7CX-A11D1-N
Type: H7CX-A Series. Classification: Preset