Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes (100 to 240 VAC only) H7ET-NFV-B-300 Communications Manual.
Control output: Contact (SPDT).
Operating mode: Up counting
H7ET-NFV-B-300
Max.counting speed: 30 cps.
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC H7ET-NFV-B-300 Communications Manual.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator H7ET-NFV-B-300 Communications Manual.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: No.
Control output: Contact (SPST-NO).
Operating mode: Reversible counting, individual inpu.
Max.counting speed: 5 kcps (see note 1.).
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Preset stage: 1-stage setting.
Nameplate lettering: English.
Nine Built-in Counters/Timers to.
Measure Equipment Operating.
Cycles and Times and Forecast.
Maintenance Timing.
Provides up to nine counters or accumulative timers.
(Counter and timer functions can be used at the same time.)
Individual forecast outputs to indicate maintenance timing.
Pre-forecast display and machine stoppage output provided H7ET-NFV-B-300 Manual.
IP54 oil-proof type at setting area for resistance to oil and water.
Separate digit keys to easily change settings.
Compact, short-body: 72 × 72 × 79 mm (DIN).
Keey protection function prevents incorrect operation H7ET-NFV-B-300 Manual.
Multiple outputs: NPN/PNP.
Directly connectable to 2-wire DC sensors.
Complies with UL and CSA.