Home >> Download >> OMRON >> Manual Download >> OMRON K2CM-2LS Communications Manual K2CM-2LS Manual

OMRON K2CM-2LS Communications Manual K2CM-2LS Manual

Product model: K2CM-2LS
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 0.29MB
Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CM-2LS Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K2CM-2LS
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-2LS Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: DC voltage input type.
Output type: DeviceNet; -; DeviceNet.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K2CM-2LS Communications Manual.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply vvoltage: AC100 ~ 240V K2CM-2LS Manual.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the coloor, can switch the green / Red 2 kinds of color display K2CM-2LS Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input
Related products
OMRON
Motor Protective Relay
K2CM-Q2MAV
OMRON Motor Protective Relay K2CM-Q2MAV
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q4HA
OMRON Motor Protective Relay K2CM-Q4HA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-1LSA
OMRON Motor Protective Relay K2CM-1LSA
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q2H
OMRON Motor Protective Relay K2CM-Q2H
Time specification: Instantaneous type. Curre