Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CM-Q1L Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K2CM-Q1L
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-Q1L Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type of input: AC voltage input.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K2CM-Q1L Manual.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table OMRON Digital Temperature Controllers Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend OMRON Digital Temperature Controllers Manual.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet typeMeasuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial OMRON Digital Temperature Controllers Manual.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automaticaally resetting supported by one Relay K2CM-Q1L Communications Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssupported K2CM-Q1L Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.