Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents K3HB-RNB-A-DRT1 Communications Manual.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A)
K3HB-RNB-A-DRT1
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. An Ideal Indicator for OK/NG Judgements in Automated and,
Picking Machines, Measuring Factors such as Pressure,
Load, Torque, and Weight Using Load Cell Signal Input K3HB-RNB-A-DRT1 Communications Manual.
Easy recognition of judgement results using color display that can be switched,
between red and green.
Equipped with a position meter for monitoring operating status trends.
External event input allows use in various measurement and discrimination, applications K3HB-RNB-A-DRT1 Communications Manual.
Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
External power takeoff of 100 mA at 10 VDC provided. (Models with 5-VDC,
power takeoff also available.).
Series expanded to include DeviceNet models.
Short body with depth of only 95 mm (from behind the front panel), or 97 mm,
for DeviceNet models.
UL certification approval (Certification Mark License).
CE Marking conformance by third party assessment body.
Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
Capable of high-speed sampling at 50 times per second (20 ms).
• Easy-to-set two-point scaling allows conversion and display of any,
user-set values. Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Starttup lock and operating time can be set separately K3HB-RNB-A-DRT1 Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and coommercial CT input,
(0 to 1 A or 0 to 5 A) supported K3HB-RNB-A-DRT1 Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.