Ideal for water level control.
Sensitivity adjustment and timer for easy usage.
Sensitivity adjustment from 10 k to 100 kΩ.
Enables easy onsite adjustment.
ON-delay timer from 0.1 to 10 s.
Ideal as countermeasure for waves on liquid surfaces.
Width of 17.5 mm to reduce space required in panels K3HB-VLC-B1 User's Manual.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires K3HB-VLC-B1
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models with transistor outputs added for low contact wear. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-VLC-B1 User's Manual.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-VLC-B1 User's Manual.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mV toStandard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 120-125-130-135-140-145-150V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work tthrough high reliability semiconductor circuits K3HB-VLC-B1 Manual.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within thhe hidden from the start to the 2S timer, can easily adjust the time K3HB-VLC-B1 Manual.
The control power of the relay is not needed, which avoids the trouble of wiring.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-E1 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-E1 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Voltage and current panel meter
K3HB-XVA-CPAC21 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-CPAC21 AC100-240
Type of input: AC voltage input. Output type
OMRON
Time interval table
K3HB-PNB-L1AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-L1AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E