LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-VLC-L2BT11 User's Manual Digital Temperature Controllers Manual

OMRON K3HB-VLC-L2BT11 User's Manual Digital Temperature Controllers Manual

Product model: K3HB-VLC-L2BT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
File size: 2.28MB
Cable length: 3 m.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously K3HB-VLC-L2BT11 Manual.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit K3HB-VLC-L2BT11
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power K3HB-VLC-L2BT11 Manual.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings K3HB-VLC-L2BT11 Manual.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) OMRON Digital Temperature Controllers Manual.
Output specifications: One relay output.
Communications output: RS-485 OMRON Digital Temperature Controllers Manual.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control OMRON Digital Tempeerature Controllers Manual K3HB-VLC-L2BT11 User's Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-VLC-L2BT11 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-E1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E1 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK3BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-FLK3BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK3ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-FLK3ET11 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-BT11 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-BT11 AC/DC24V
Category: external supply 100mA DC10V. Input