OMRON K3HB-VLC-E-DRT1 Manual K3HB-VLC-E-DRT1 Communications Manual

Product model: K3HB-VLC-E-DRT1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 1.84MB
Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately K3HB-VLC-E-DRT1 Communications Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load) K3HB-VLC-E-DRT1
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Category: external supply 100mA DC10V K3HB-VLC-E-DRT1 Communications Manual.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-E-DRT1 Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurementTime specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K3HB-VLC-E-DRT1 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-E-DRT1 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK3ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-FLK3ET11 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK1ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-FLK1ET11 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK1ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-FLK1ET11 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC100-240
Category: external supply 100mA DC5V type. I