Product model: K3HB-XAA-FLK1AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 2.07MB
Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XAA-FLK1AT11 Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-XAA-FLK1AT11
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAA-FLK1AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 1 to 2 A.
Accurate Detection of Heater Element K3HB-XAA-FLK1AT11 Manual.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out OMRON Digital Temperature Controllers Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters OMRON Digital Temperature Controllers Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) OMRON Digital Temperature Controllers Manual.
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase conntrol, and cyclic control K3HB-XAA-FLK1AT11 Communications Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-XAA-FLK1AT11 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Voltage and current panel meter
K3HB-XAA-T11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-T11 AC100-240
Type of input: AC current input. Output type
OMRON
Voltage and current panel meter
K3HB-XVD-FLK1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-FLK1AT11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XAA-FLK3AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-FLK3AT11 AC/DC24
Type of input: AC current input. Output type