Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes K3HB-XAD-FLK1AT11 .
Action determine the color, can switch the green / Red 2 kinds of color display
K3HB-XAD-FLK1AT11
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeviceTime specification: Inverse type.
Current setting range: 50 to 160 A K3HB-XAD-FLK1AT11 .
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K3HB-XAD-FLK1AT11 .
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Product: Shower Nozzle; 60°.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-XAD-FLK1AT11 Communications Manual.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can bbe switched between normally open and normally closed K3HB-XAD-FLK1AT11 Communications Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.