LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-XAD-FLK3AT11 User's Manual

OMRON K3HB-XAD-FLK3AT11 User's Manual

Product model: K3HB-XAD-FLK3AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
File size: 2.28MB
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XAD-FLK3AT11 K3HB-XAD-FLK3AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputs can be applied to a variety of measurement and identificationType of input: AC current input K3HB-XAD-FLK3AT11 .
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XAD-FLK3AT11 .
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type. Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the sttart of operation K3HB-XAD-FLK3AT11 User's Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAD-FLK3AT11 User's Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Rotating pulse meter
K3HB-RPB-FLK3AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-FLK3AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Rotating pulse meter
K3HB-RNB-FLK3AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-FLK3AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XAD-CPAC21 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-CPAC21 AC100-240
Input type: DC current input. Output type: r
OMRON
Temperature panel
K3HB-HTA-FLK3AT11 AC100-240
OMRON Temperature panel K3HB-HTA-FLK3AT11 AC100-240
Type of input: platinum resistance / thermoco