Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 300W.
Output voltage: 5V.
Output current: 60A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device S8BW-C02 Connection Guide.
Built in support for determining the abnormal causes of the new under voltage detection function
S8BW-C02
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage S8BW-C02 Connection Guide.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2 S8BW-C02 Connection Guide. (except for type 15/30W)
"
Appearance: insert type.
Control supply voltage: DC24V.
Action elements: overload detection.
Action characteristic: lock, instant action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc., are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple. Input voltage: 24 VDC (24 to 28 VDC).
Output voltage(during backup operation): 22.5 V.
Output current: 2.5 A.
Prevents Equipment Stoppage, Data Loss,
and Other Problems Resulting from Momentary.
Power Failures.
Provides a backup time of 5500 ms at an output current of 2 S8BW-C02 Manual. 5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
Parallel connections to up to four Blocks can be used to increase,,
the backup time and current capacities S8BW-C02 Manual.
Complies with SEMI F47-0200 standard.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C.