Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 100/110 VDC.
Overcurrent detection: Instantaneous type, W/o start-up lock.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available S8EX-N03012LC .
Instantaneous type under current sensor available
S8EX-N03012LC
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). Category: incidental cover with under voltage detection function.
Structure: bottom mounting type.
Capacity: 30W.
Output voltage: 24V.
Output current: 0.65A.
Alarm output: -.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device S8EX-N03012LC .
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products S8EX-N03012LC .
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Power ratings: 180 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 7.5 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models wiith screwless terminal blocks and,
indication monitor S8EX-N03012LC EtherNet/IP Connection Guide.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8EX-N03012LC EtherNet/IP Connection Guide.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)