Communications: Supported (RS-232C).
UL Class 2 output: Not compliant.
Complete Flexible DC Circuit Protector That.
Has a Wide Array of Displays, Alarm,
Outputs, and Other Digital Functions.
Four circuit protectors in one package.
Simple setting of current tripping values for each branch outputs,
in 0 S8VM-03024A . 1-A units.
Startup and shutdown sequence control.
Display and alarm functions (Input voltage, output current,
run time, and over-temperature),
Outputs conform to UL Class 2 (at 24 VDC, S8M-CP04-RS only),
DIN Rail mounting
S8VM-03024A
RoHs-compliant.
Free Support Tool available. Power ratings: 120 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current: 5 A S8VM-03024A .
Boost Current: 6 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120% S8VM-03024A .
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Power ratings: 60 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 12 V.
Output current: 4.5 A.
Boost Current: 5.4 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL5008/60950-1, CSA C22 S8VM-03024A Connection Guide. 2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 4800-W models) S8VM-03024A Connection Guide.
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1.