Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 50 W.
Output voltage: 5 V.
Output current: 10 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) S8VM-05005C Manual.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available
S8VM-05005C
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) S8VM-05005C Manual.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 5V.
Output current: 10A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device S8VM-05005C Manual.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products OMRON Digital Controller Manual.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage OMRON Digital Controller Manual.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer OMRON Digital Controller Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (general purpose).
Inner diameter (D)of seal rubber: 11 mm.
External diameter of cable: Min, 9 mm; Max, 11 mm.
Applicabble model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 S8VM-05005C Connection Guide.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch S8VM-05005C Manual.