Model: CPM2C-20C1DTC-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: Yes.Unit: 10 points (6 inputs/4outputs); Connector model.
Inputs: 6 points at 24 VDC.
Outputs: 4 transistor sinking outputs CP1L-L10DT-D Manual.
Clock: Yes.
Ultra-compact, Thin-profile CPM2C CPU.
Unit with CompoBus/S Master Offering
CP1L-L10DT-D
High-speed Bus Communications with,
No Complicated Wiring.
Ultra-compact, thin-profile design ideal for on-site,
applications.
Ultra-compact at 40 x 90 x 65 mm (W x H x D) with.
10 I/O points and CompoBus/S Master offers.
versatile expandability to construct systems.
meeting on-site needs CP1L-L10DT-D Manual.
A large number of expansion I/O points reduces,
system construction cost.
Up to three Expansion Terminals can be,
connected. Furthermore, CompoBus/S Remote,
Terminals can be used for expansion I/O points.
Not only in-panel wiring but also external wiring is,
simplified. Furthermore, the miniaturization of the,
control panel reduces cable, terminal block, and wiring costs.
Easy System Designing, Modification, and Expan sion CP1L-L10DT-D Manual.
CompoBus/S Remote Terminals with high-speed.
bus communications and no complicated wiring.
can be used as expansion terminal blocks with,
minimal modifications as long as room for,
expansion is reserved at the designing stage OMRON CP1L-L10DT-D REFERENCE MANUAL.
A calendar/clock ensures easy machinery control,
including data collection and error logs with date,
and time stamps OMRON CP1L-L10DT-D REFERENCE MANUAL. This functionality can be used as,
a weekly timer as well. Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced OMRON CP1L-L10DT-D REFERENCE MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gaateway Unit,
helps to detect errors on site CP1L-L10DT-D .
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specification: Platinum resistancee thermometer input (Pt100, JPt100),
heater burnout alarm,
manual operation,
ON/OFF or advanced PID control,
transistor (NPN) output, 2 loops CP1L-L10DT-D Manual.