I/O classification: Digital I/O.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method: M3 terminal block.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points OMRON S8EX-BP15048 Connection Guide.
Incorporates easy-to-wire terminals each,
connecting to a single wire
S8EX-BP15048
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 50W.
Output voltage: 15V.
Output current: 3 OMRON S8EX-BP15048 Connection Guide. 5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products OMRON S8EX-BP15048 Connection Guide.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 100/110/120 VAC.
Overcurrent detection: Instantaneous type, W/o start-up lock.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). Type: open type.
Structure: bottom mounting type.
Capacity: 100W.
Output voltage: 12V.
Output current: 8.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Suppoort finger touch protection to prevent electric shock S8EX-BP15048 Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer S8EX-BP15048 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)