Control power supply voltage: 24 VDC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) OMRON S8JX-G15024CD EtherNet/IP Connection Guide.
Detect three-phase AC current for under and/or overcur,
rent using current converter
S8JX-G15024CD
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) OMRON S8JX-G15024CD EtherNet/IP Connection Guide.
LED operation indicator.
UL/CSA approval (SDV-F@). Control voltage: 200/220/240 VAC.
Reset: Automatic.
Model: Instantaneous type (See note 1.).
Solid-state Relay Provides Three Operating.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase.
LEDs indicate operation of the selected operating function OMRON S8JX-G15024CD EtherNet/IP Connection Guide.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s.
Protects the motor from reversing without starting it.
before using the K2CM. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 1500W.
Output voltage: 24V.
Output current: 65A (AC100V) 70A (AC200V) peak current 105A (AC200V).
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock S8JX-G15024CD Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer S8JX-G15024CD Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"