LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> S8JX-P05024C Manual OMRON S8JX-P05024C EtherNet/IP Connection Guide

S8JX-P05024C Manual OMRON S8JX-P05024C EtherNet/IP Connection Guide

Product model: S8JX-P05024C
Name: Digital Controller
Brand: OMRON
Sort: EtherNet/IP Connection Guide
File language: English
File size: 2.48MB
Power supply (commercial AC power supply) power cut detector for monitoring and control device.
Instantaneous detection voltage drop, power failure, instantaneous power failure.
Small, easy to install DIN guide rail mounting type.
Input voltage is divided into AC100V, AC200V two specifications. Power ratings: 120 W OMRON S8JX-P05024C EtherNet/IP Connection Guide.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3) S8JX-P05024C
Output voltage: 24 V.
Output current: 5 A.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards OMRON S8JX-P05024C EtherNet/IP Connection Guide.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards OMRON S8JX-P05024C EtherNet/IP Connection Guide. ) Control power supply voltage: 100/110 VDC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Input voltage: 24 VDC (24 to 28 VDC).
Output voltage(during backup operation): 22.5 V.
Output current: 2.5 A.
Prevents Equipment Stoppage, Data Loss,
and Other Problems Resulting from Momentary.
Power Failures.
Provides a backup time of 500 mms at an output current of 2 S8JX-P05024C Manual. 5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
Parallel connections to up to four Blocks can be used to increase,,
the backup time and current capacities S8JX-P05024C Manual.
Complies with SEMI F47-0200 standard.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C.
Related products
OMRON
Switching Mode Power Supply
S8JC-ZS05024C-AC2
OMRON Switching Mode Power Supply S8JC-ZS05024C-AC2
Type: S8JC-ZS series models list. Meet the cr
OMRON
Switching Mode Power Supply
S8VM-05024C
OMRON Switching Mode Power Supply S8VM-05024C
Category: incidental cover type. Structure:
OMRON
Switching Mode Power Supply
S8VM-05024CD
OMRON Switching Mode Power Supply S8VM-05024CD
Category: incidental cover type. Structure: D
OMRON
Switching Mode Power Supply
S8JC-Z05024CD
OMRON Switching Mode Power Supply S8JC-Z05024CD
Type: S8JC-Z series models list. Meet the cri