Master unit provides data exchange, diagnostics and message communications.
Network type : Profibus-DP.
CJ1W-PRM21 Rating : 12 Mbps; 1200 m distance; 125 nodes; shielded twisted pair cable; allows 7, 168 words of I/O data per PLL; one RS-485 port.Product name: N@@S1- type CPU Units with 40 I/O Points C500-RT002-PEV1 SETUP MANUAL.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 24; Outputs, 16;
Output type: Relay
C500-RT002-PEV1
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.09A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality C500-RT002-PEV1 SETUP MANUAL.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Name: Temperature Control Module.
Model: C200H-TC001.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Transistor outputModel: C200H-MD215.
No. of I/O pts: 16 inputs, 16 outputs C500-RT002-PEV1 SETUP MANUAL.
Specifications: 24VDC.Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON C500-RT002-PEV1 Manual.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON C500-RT002-PEV1 Manual.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON C500-RT002-PEV1 Manual. Name: PID Control Module.
Model: C200H-PID01.
Output: Transistor output (open collector).Specifications: Two RS-422A/485 ports.Model: CPM2C-32EDT1M. Units with 32 I/O points
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.C500-OA I/O Unit Triac Output 16 pts C500-OA226.
AC250V 1.2A.Model: C200HW-ME32K.
Capacity: 32K words.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compareed,
with previous systems C500-RT002-PEV1 .
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems C500-RT002-PEV1 SETUP MANUAL.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.