Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CC-TQX3DSM-066 Manual.
Ideal for the thermal input devices of Temperature Controllers
E5CC-TQX3DSM-066
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, 2-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control E5CC-TQX3DSM-066 Manual.
Outputs(control/transfer): 4 points: Pulse voltage (2 points) and
Pulse voltage/current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity E5CC-TQX3DSM-066 Manual.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller OMRON E5CC-TQX3DSM-066 lnstruction Manual.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 OMRON E5CC-TQX3DSM-066 lnstruction Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming OMRON E5CC-TQX3DSM-066 lnstruction Manual. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuaal, RUN/STOP, alarm), interactive display PV/SV E5CC-TQX3DSM-066 RS-485 CompoWay/F.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CC-TQX3DSM-066 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.