Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Fitting materials: Stainless steel (SUS304).
Count: 1.
Accessories: Description, xagonal bolts M4 (with spring and plain washers); Material, Iron, zinc plating; Count, 2 E5AC-TCX4ASM-065 Manual
E5AC-TCX4ASM-065
Applicable sensor (mounting pitch on sensor side): E3S-C (25.4).
Page: Dimensions, 8.
Size: 96 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V E5AC-TCX4ASM-065 Manual.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications E5AC-TCX4ASM-065 Manual.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply OMRON E5AC-TCX4ASM-065 lnstruction Manual.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON E5AC-TCX4ASM-065 lnstruction Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC) OMRON E5AC-TCX4ASM-065 lnstruction Manual.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature SSensors E5AC-TCX4ASM-065 RS-485 CompoWay/F.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AC-TCX4ASM-065 Manual.