Connection method: Pre-wired.
Cable length: 5 m.
Sensing distance: 100 ± 35 mm.
Model: NPN output.
A CMOS Laser Sensor That’s.
Optimum for Simple Measurements.
A resolution of 0.002 mm that’s suitable for simple measure ments.
Stable measurements for any type of workpiece.
Models available with four different distance specifications OMRON ZX-LD100 Introduction Manual.
Long-distance model for up to 1,000 mm
ZX-LD100 Optical system: diffuse type.
Detection distance: 80 positive and negative 15mm.
Beam shape: linear beam.
Beam diameter: 900mm * 60 M.
Resolution: 2 m.
Cable length: 0.5m. Power supply: DC.
Output type: PNP.
Measurable at any position.
The usual limitations, such as the ''measurement,
area being confined to the center''
or ''large errors due to positioning'',
that used to plague laser measuring sensors,
have now been overcome OMRON ZX-LD100 Introduction Manual. Measurements can be,
consistently taken within a 500 mm area,
whatever stage the work is at or whichever way it is inserted.
It can now be set to positions without interference from,
the work feed and without limitations of size of work area. Connection method: Pre-wired OMRON ZX-LD100 Introduction Manual.
Cable length: 5 m.
Sensing distance: 100 ± 35 mm.
Model: PNP output.
A CMOS Laser Sensor That’s.
Optimum for Simple Measurements.
A resolution of 0.002 mm that’s suitable for simple measure ments.
Stable measurements for any type of workpiece.
Models available with four different distance specifications.
Long-distance model for up to 1,000 mm. Ultra high performance sensors support the core quality of large scale ultra precision measurement.
Measurement center distance of 20 ~ 1500 mm of various models.
Maximum resolution of 0.25 mu m.
Maximum response speed of 110 Mu s.
Support parallel output.
Best size / stability.
Sensor size.
Pay attention to the performance of the best sensor head size and 3 point type fixed structure to ensure superior sensing stability.
Excellent mobile resolution.
Perspective resolution enhancement.
By improving the sensitivity and resolution of the optical lens,
Optimization of optical system,
Therebyy greatly reducing the motion resolution error (due to the location of the workpiece surface caused by the error) ZX-LD100 Manual. Cable length: 2 m.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meeticulous ionization ZX-LD100 Manual.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings.