Specification: three phase 200V.
Power: 0.2KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of thee inverter --3G3MZ 3G2A5-CT012.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G2A5-CT012.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice 3G2A5-CT012. Specification: three phase 200V.
Power: 5.5KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence).
Rated voltage: three phase 240V ~ 50/60Hz AC200 OMRON 3G2A5-CT012.
Weight: about 4kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact OMRON 3G2A5-CT012.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function OMRON 3G2A5-CT012.
Colorful function.
Brake transistor built-in.
Protection function.
Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 5.5 square mm.
Weight: 0.8kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Function name: three phase 400V.
Power: 0.4KW.
Maximum output voltage: three phase 380 ~ 480VAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.<
Compact size and uniform, and can be installed close to the side by side 3G2A5-CT012.
Signal output function for controlling external brake action.
Software setting operation mode, no need to connect the control line can be used for speed control.