3G2A5-DA001 OMRON 3G2A5-DA001


Frequency converter input power: 3 phase AC400V.
Weight: 7.0KG.
Standard applicable line diameter: 38 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor 3G2A5-DA001. Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 100A. Weight: 8.4KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection.
Function name: single phase 200V 3G2A5-DA001.
Power: 2.2KW.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage).
Rated voltage, frequency: single phase power supply 200 ~ 50/60Hz, 240V.
Cooling: forced cooling.
Weight: 1.9kg.
Simple but not simple, casual and not casual 3G2A5-DA001.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function OMRON 3G2A5-DA001.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action.
Software setting operation mode, no need to connect the control line can be used for speed control. Function name: 3 phase 200V.
Power: 11KW OMRON 3G2A5-DA001.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 5.1KG.
Dimension (w * h) 296mm *:180.
Outline dimension (deep):175mm.
Mechanical automation concept OMRON 3G2A5-DA001.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Box protection class: plastic, IP00.
Terminal size: M5.
Line diameter: 8 square mm.
Weight: 1.4kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Box protection class: plastic, IP00.
Termminal size: M4 3G2A5-DA001.
Line diameter: 2 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection.