LK Automation Limited
Home >> Supply >> AJ65VBTCE3-32DTE MITSUBISHI AJ65VBTCE3-32DTE Sensor connector type DC input / transistor output module
Search
Information sort

AJ65VBTCE3-32DTE MITSUBISHI AJ65VBTCE3-32DTE Sensor connector type DC input / transistor output module


MELSECNET (II).
Optical fiber loop. Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
> Choose from a rich product lineup AJ65VBTCE3-32DTE.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ65VBTCE3-32DTE.
Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA AJ65VBTCE3-32DTE.
Output form: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type).
Using industry standard E-CON type MITSUBISHI AJ65VBTCE3-32DTE.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Cable length: 0.5 meters.
For the GOT and the PC card interface unit (A1SD59J-MIF) connection.
For FXCPU expansion board FX2N-422-B, FX1N-422-BD and GOT connection MITSUBISHI AJ65VBTCE3-32DTE. Cable length: 3 meters.
For GOT and parallel printer connection. Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0 MITSUBISHI AJ65VBTCE3-32DTE.1A.
External connection: 1 wire.
40 pin connector type (FCN connector type).
Through the 40 pin connector type (FCN connector type) can be connected to a variety of devices.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The ssimulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness AJ65VBTCE3-32DTE.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.