LK Automation Limited
Home >> Supply >> C200HW-BC101-V1 OMRON C200HW-BC101-V1 CPU Backplane
Search
Information sort

C200HW-BC101-V1 OMRON C200HW-BC101-V1 CPU Backplane


Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No C200HW-BC101-V1. of axes: 16 aaxes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management C200HW-BC101-V1.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association C200HW-BC101-V1. Name: Loop-control CPU Unit.
I/O bits: 960 bits.
Program capacity: 20K steps.
DM words: 32K words.
EM words: 32K words × 1 bank E0_00000 to E0_32767.
Versatile Machine Control with the,
Highest Performance Standards in the Industry.
Model: C200HW-BC101-V1 OMRON C200HW-BC101-V1.
No. of I/O slots: 10 slots.Specification: 16 output points.CV500-CN Cable Motion Control Connecting Cables 6 m CV500-CN624Power supply: AC power supply.
Output method: Relay output.
Inputs points: 18 points.
Outputs points: 12 points.Unit type: CS1 Special I/O Units OMRON C200HW-BC101-V1.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/8 inputs.
Externa connection: Removable erminal block OMRON C200HW-BC101-V1.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems C200HW-BC101-V1.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Related supply information