C500F-CPUA1-E OMRON C500F-CPUA1-E


Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0 C500F-CPUA1-E.21A; 24 V,0.07A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economiccal, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality C500F-CPUA1-E.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: C200HW-COM04-V1.
Specifications: Communications port for the Controller Link, SYSMAC LINK Units, one RS-232C port, and a protocol macro function C500F-CPUA1-E.
Number of inputs: 32 pts.
Input Voltage: 24V DC.
Input Current: 4 mA.CPU Unit: CP1H-X CPU Units.
Specifications: CPU type, Memory capacity: 20K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 24; Output, 16 OMRON C500F-CPUA1-E.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O OMRON C500F-CPUA1-E.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O. Name: Host Link Module.
Model: C200H-LK202-V1.
Communication ports: 1 RS-422.Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON C500F-CPUA1-E.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Output method: Analog resolution: 1/6000.
Analog Inpuuts: 2 C500F-CPUA1-E.
Analog Outputs: 1.100 to 120/200 to 240 VAC (Supports SYSMAC LINK and SYSMAC NET Link Systems.)Power supply: AC power supply.
Output method: Transistor output source type.
Inputs points: 24 points.
Outputs points: 16 points.