Name: AC Power Supply Unit.
Power supply voltage:
100 to 120 V AC or 200 to 240 V AC.
Output capacity: 5 VDC output capacity, 7A;
26 VDC output capacity, 1.3A;
Total, 35W.
Options: 24 V DC service power supply, No;
RUN output, Yes.
Standards: UC1, N, L, CE CS1W-BI083.
Redundant CPU Units , Power Supply Units ,
Communicationns Units ,
and Expansion I/O Cables. C500-NC Special I/O Unit C/CV Servo Module Single Axis Stepper C500-NC111-V1.
Product name: CS1 Expansion Backplanes CS1W-BI083.
Specifications: For both CS/C200H-series,
Units; 8 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes CS1W-BI083.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control OMRON CS1W-BI083. Model: CPM2C-PA201. Input: 100 to 240 V AC.Output: 24 V DC/600 mA.Model: C200H-IA122V.
No. of inputs: 16 pts.
Input voltage: 100 to 120 VAC, +10%/–15%.
Input current: 10mA, 100VAC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks OMRON CS1W-BI083.
Inputs percom-mon: 16 pts.
Internal currentcon-sump-tiUnit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs OMRON CS1W-BI083.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CS1W-BI083.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.