CV500-RT221 OMRON CV500-RT221 Remote I/O Master Unit


Model: C200HW-PA204.
Supply voltage: 100 to 120 VAC, 200 to 240 VAC.
Comments: ---.Communications protocol: Dedicated CompoBus/S protoco.
Code: Manchester code.
CV500-RT SYSMAC BUS Remote I/O Slave Unit (wired) CV500-RT221.
Wire Type.Output method: Analog resolution: 1/6000.
Analog Inputs: 2 CV500-RT221.
Analog Outputs: 1.Unit type: CS1 Basic I/OO Units.
Product name: Relay Output Units.
Specifications: 12 to 24 VDC,
0.5A . 16 outputs; Sinking.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No CV500-RT221.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.17A;
26 V system, -- CV500-RT221.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality OMRON CV500-RT221.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Power supply: AC power supply.
Output method: Relay output.
Inputs points: 18 points OMRON CV500-RT221.
Outputs points: 12 points.Name: Analog I/O Slave Units.
Specifications: Analog inputs;
4 inputs.
Standards: CE, U, U1, C, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON CV500-RT221.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CV500-RT221.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.