Max input / output points: 14 points.
Power supply voltage: DC24V.
Input points: 8 points.
Output points: 6 points.
Output type: transistor.
Power consumption (W): 32.
Weight (kg):0.4.
Size (WxHxD) mm:90x90x75.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion boarrd FR-A820-1.5K-1.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect FR-A820-1.5K-1.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control. Input and output points: 20 points FR-A820-1.5K-1.
Power supply: AC100-240V.
Input points: 12 points.
Output points: 8 points.
Output form: transistor output (source).
Power consumption: 20W.
Weight: 0.4KG.
Outline dimension: 75x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features MITSUBISHI FR-A820-1.5K-1.
Special adaptor and function expansion board can be installed and used FX3 series.
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps MITSUBISHI FR-A820-1.5K-1.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models.
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on MITSUBISHI FR-A820-1.5K-1.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on.
MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 500KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, thee current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor FR-A820-1.5K-1.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.