FX3U-485ADP-MB MITSUBISHI FX3U-485ADP-MB RS-485 communication


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Max input / output points: 30 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 14 points.
Output type: Transistor (source).
Power consumption (W): 21 FX3U-485ADP-MB.
Weight (kg):0.45.
Size (WxHxD) mm:100x90x75..
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14 FX3U-485ADP-MB.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0 FX3U-485ADP-MB.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment.
RS-485 communication. Special communication adapter.MITSUBISHI inverter FR-F720 series MITSUBISHI FX3U-485ADP-MB.
Voltage level: three phase 200V.
Frequency converter capacity: 90KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes MITSUBISHI FX3U-485ADP-MB.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall MITSUBISHI FX3U-485ADP-MB. Function: RS-485 communication.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 22kw.
SLD converter rated current: 125A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the mosst suitable FX3U-485ADP-MB.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.