The analog output adapter (FX3U- - racy -BD)MITSUBISHI inverter FR-D720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 0.2KW.
Vector control variable frequency speed control is the practice of the asynchronous motor in the three-phase coordinate system of the stator current Ia, Ib, Ic, through the three-phase to two-phase transformation,
Thhe alternating current of Ia1Ib1 is equivalent to a two phase stationary coordinate system, and then is rotated by the rotor field oriented,
Equivalent to the DC current Im1, It1 (Im1 equivalent to DC motor excitation current in synchronous rotating coordinate system;
It1 equal to the armature current proportional to the torque, and then imitate the DC motor control method, to obtain the DC motor control,
The control of asynchronous motor is realized through the corresponding inverse coordinate transformation FR-D740-7 FR-D740-7 FR-D740-7.5K-CHT.5K-CHT.5K-CHT.
MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 7.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI FR-D740-7.5K-CHT.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used MITSUBISHI FR-D740-7.5K-CHT. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft MITSUBISHI FR-D740-7.5K-CHT. Max input / output points: 14 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 6 points.
Output type: Transistor (source).
Power consumption (W): 6.5.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.<
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FR-D740-7.5K-CHT.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.