MITSUBISHI FX1S-14MR-D PLC MITSUBISHI FX1S-14MR-D


Use: this option can be selected from the open collector output can output 2 analog signal from the transducer output signal in the standard 6 digital signal.
Applicable frequency converter: FR-A700, FR-F700, FR-E700. "Max input / output points: 32 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points FX1S-14MR-D.
Output points: 16 points.
Output type: Transistor (sinktype).
Power consumption: 40VA.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter FX1S-14MR-D.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit FX1S-14MR-D.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate MITSUBISHI FX1S-14MR-D.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard MITSUBISHI FX1S-14MR-D.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Max input / output points: 14 points.
Power supply voltage: DC24V MITSUBISHI FX1S-14MR-D.
Input points: 8 points.
Output points: 6 points.
Output type: relay.
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.<
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FX1S-14MR-D.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.