Power supply voltage: 100 to 240 VAC.
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple or platinum resistance thermometer.
Setting units (setting range): Setting unit: 1°C or 1°F (0 to 999°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored OMRON S82K-00315.
Temperature monitoring in slim design with a width of just 22
S82K-003155 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation OMRON S82K-00315.
Alarm status identification with LED indicator .
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF. Product name: CS1 CPU Backplane.
Specifications: For both CS/C200H-series Units,
Units cannot be mounted; 3 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes OMRON S82K-00315.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Classification: Standard models.
Rated voltage: Standard products, 24, 100/110, 200/220, or 220/240 VAC,
12, 24, or 100/110 VDC; Made-to-order items, 12, or 110/120 VAC, 48 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Count input: No-voltage input.
Dissplay: 7-segmennt LCD S82K-00315.
Max. revolutions displayed (applicable encoder resolution):
1000 s–1 (1 pulse/rev.), 1000 min–1 (60 pulse/rev.); Black body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution ussed;
1000 s–1/1000 min–1 or 1000 S82K-00315. 0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1.
S82K-00315 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=S82K-00315&select=5