Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater OMRON SGE-245-0-1270 02500C-02500C.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input
SGE-245-0-1270 02500C-02500C
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance OMRON SGE-245-0-1270 02500C-02500C.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved .
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP OMRON SGE-245-0-1270 02500C-02500C.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV .
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Ideal to prevent heater overheating.
Self-latching output to contribute to safe,
equipment operation.
Set the temperature with ultra-simple rotary switches.
Digitally set the temperature to between 0 and 999°C in 1°C increments with one,
Relay (K8DT-TH1@@).
(K8DT-TH2@@: Set to between 0 and 1,800°C in 10°C increments.).
Connect a thermocouple or platinum resistance thermometer.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability. Detect errors in motors and other equipment,
through current changes.
Monitor for overcurrents and undercurrents,
simultaneously with one Relay.
Monitor AC or DC currents with one Relay.
Use with commercially availabble CTs (CT secondary side: 0 to 1 A or 0 to 5 A) SGE-245-0-1270 02500C-02500C.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crrosssover wiring (all terminals) SGE-245-0-1270 02500C-02500C.
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability.
SGE-245-0-1270 02500C-02500C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-245-0-1270 02500C-02500C&select=5