Power ratings: 15 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 12 V.
Output current: 1.2 A.
Boost Current: 1.44 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market OMRON SGE-365-2-1500 02000C.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC
SGE-365-2-1500 02000C
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1 OMRON SGE-365-2-1500 02000C.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16 .
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20 OMRON SGE-365-2-1500 02000C.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now .
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Arm lever.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. I/O classification: Output.
I/O points: 16.
Internal I/O circuit common: PNP (– common).
Rated voltage: 12 VDC, 24 VDC.
Single Cable Connection to PLC Means.
Space is Saved and Less Control Panel.
Wiring is Required.
Compact size: 182 (W) 85 (D) 68 (H) mm,
(8-point Outputt Block width is 102 mm) . SGE-365-2-1500 02000C.
Connects to the PC through the connecting cable,
(G79 Series) and connector, and requires only a,
snap-in operation.
Surge suppressor circuit built-in.
Immediate recognition of I/O signal status using,
LED operation inndicators SGE-365-2-1500 02000C.
G3TA I/O Solid-state relay can be mounted instead,
of G7T.
Mounts easily on a DIN track.
Approved by UL, CSA (except for G7TC-OC16-1).
SGE-365-2-1500 02000C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-365-2-1500 02000C&select=5