LK Automation Limited
Home >> Price >> OMRON >> OMRON WL-2A129 WL-2A129
Brand sort

OMRON WL-2A129 WL-2A129

No PHOTO
Country: JAPAN
Name:
Model: WL-2A129
Market price: U.S.$ 0
(The following are the market open price not sales price!)
next one: OMRON WL-2A122
Last one: OMRON WL-2H4100
OMRON WL-2A129
Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON WL-2A129.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that WL-2A129
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22 OMRON WL-2A129. 2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) .
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Number of notches: 3 notches.
Output: DPDT.
Reset method: Manual.
Key release position: Right.
Separate Construction with Cylindrical.
16-dia. Body.
Short mounting depth, less than 28 OMRON WL-2A129. 5 mm below panel.
Wide range of switching capacity from standard to microload .
Oil-resistant IP65 models. Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Alarm output: source type.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W outpput terminalss)
Support finger touch protection to prevent electric shock WL-2A129.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhenn the fan is replaced by the customer WL-2A129. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"