LK Automation Limited
Home >> Price >> OMRON >> OMRON WLG2-55LDS-M1GJ-N WLG2-55LDS-M1GJ-N
Brand sort

OMRON WLG2-55LDS-M1GJ-N WLG2-55LDS-M1GJ-N

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON WLG2-55LDS-M1GJ-N
Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Alarm output: -.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON WLG2-55LDS-M1GJ-N.
Built in support for determining the abnormal causes of the new under voltage detection function WLG2-55LDS-M1GJ-N
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products OMRON WLG2-55LDS-M1GJ-N.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage .
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer OMRON WLG2-55LDS-M1GJ-N. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2 . (except for type 15/30W)
"

Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms. (Default setting: 1 ms)
Number of circuits per common: 8 points/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Input device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,

among multiple contaccts WLG2-55LDS-M1GJ-N.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,

swwitch and with tool software WLG2-55LDS-M1GJ-N.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.
WLG2-55LDS-M1GJ-N Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=WLG2-55LDS-M1GJ-N&select=5