Size: M30 (brass), single distance, non shield type.
Detection distance: 20mm.
Connection mode: lead type (cable length is 2M and 5m two).
Thread length: Standard type.
Output type: PNP.
Action mode NC.
Set up the new standard of the world economy proximity sensor.
OMRON as a pioneer and leader in proximity sensor industry,
Now bring you a new E2B proximity sensor with high performance to price ratio
WLGCA2-2
This series of products are complete,
Aimed at reasonable prices to meet customer demand for high quality and high reliability of the sensor.
We have tested the product not only on the protection level (IP67) specific item,
The oil spray test was carried out on the condition of the work site OMRON WLGCA2-2.
Simulation test was carried out in the environment of high oil mist concentration . Appearance: Flat,Unshielded.
Sensing distance (variable): 10 mm(4 to 10 mm).
Flat Capacitive Sensor with Separate.
Amplifier.
Ideal for Mounting on Robot Hands.
Flat head is only 5.5-mm thick.
Robotics cable ensures improved flexibility.
Operation indicator on the Sensor OMRON WLGCA2-2.
Easy-to-use connector. Sensing method: Narrow-beam reflective .
Connection method: Pre-wired.
Sensing distance: 90±30 mm.
Model: PNP output.
Small 2.5-mm-diameter Spot Ideal for.
Detecting Small Workpieces.
Tiny workpieces as little as 0.1 mm in diameter can be,
detected with the 2.5-mm-dia. spot.
The narrow beam enables sensing from small slots or holes.
The small spot of light enables visual checking of sensing,
spot position.
IP67 degree of protection, mutual interference prevention,
and EN standard compliance. Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Sealed crossroller plunger.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulatinng material . WLGCA2-2.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
conffirrmation of operation WLGCA2-2.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
WLGCA2-2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WLGCA2-2&select=5