Fitting materials: Iron, zinc plating.
Count: 1 .
Accessories: Description, Phillips screws M2.3 × 8,
Spring washer M2.3;
Material, Iron, zinc plating, Iron, zinc plating;
Count, 4; 4 .
Applicable sensor (mounting pitch on sensor side): E3C-S10 (7.5).
Page: Dimensions, 12. Size: 96 x 96mm.
Control output 1: double relay (proportional valve) OMRON XM4L-1541-502.
Auxiliary (alarm) output: 4.
Transfer output: have
XM4L-1541-502
Event input: 4.
Communication: RS-485.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications OMRON XM4L-1541-502.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility .
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms OMRON XM4L-1541-502.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications .
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog inputs.
(Channel Insulation); 2 inputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.18 to 0.3mm; 0.5 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Crimping.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 reequirements and ennsure a,
94V-0 fire retardant rating XM4L-1541-502.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnnector Assembly: Crimping, soldering, and screw-on XM4L-1541-502.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
XM4L-1541-502 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XM4L-1541-502&select=5