LK Automation Limited
Home >> Price >> OMRON >> OMRON XW2Z-050J-A14 XW2Z-050J-A14
Brand sort

OMRON XW2Z-050J-A14 XW2Z-050J-A14

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON XW2Z-050J-A14
Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 XW2Z-050J-A14
External connections: Screw terminals OMRON XW2Z-050J-A14.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT) .
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications OMRON XW2Z-050J-A14. Isolation: Photocoupler.
Zero cross function: Yes .
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 4 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations) XW2Z-050J-A14.
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be perrfoormed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification XW2Z-050J-A14.
XW2Z-050J-A14 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=XW2Z-050J-A14&select=5


...more relevant model market price >>>>