Field of view: Wide View (Short-distance).
Number of pixels: 760,000 pixels.
Color: PNP.
Field of view/Installation distance: Refer to figure 8 on p.20.
Inspection capabilities, camera options,
and communication options -- this powerful,
heavy weight has it all.
This Vision Sensor provides all of the best-selling,
features found in high-end models without the,
need as in vision system for a separate controller
SGE-125-5-1680 00500C-00200F
This new Smart Camera was designed to attract,
potential customers to try the FQ2 Series. Control output: Time-limit SPDT and Instantaneous SPDT.
Supply voltage: 220 VAC (50/60 Hz) OMRON SGE-125-5-1680 00500C-00200F.
Solid-state Timer with Single Time Range.
and Operating Mode.
Time range: H3BA-X8HA (0 . 05 s to 12 h),
H3BA-X8HB (0.3 s to 30 h),
H3BA-X8HC (0.6 s to 60 h).
Operating mode: ON-delay only.
Pin type: 8-pin only. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / connector type OMRON SGE-125-5-1680 00500C-00200F.
Shape: shield, M18.
Detection range: 5mm.
Output configuration: NPN.
Action mode: NO. Name: Safety I/O Terminals .
No. of I/O points: Safety inputs: 4, safety outputs (relay): 4, test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineup includes four models to accommodate various,
I/O types and number of I/O points.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system. Input voltage: 24 VDC.
Output voltage: 24 VDC.
Output current/capacity: 5 A/120 W.
Compact DC-DC UPS with a DIN rail for,
mounting, best suited for prevention of,
voltage drop and power failure in,
industrial-purpose computers.
(IPC)/controllers.
System reliability greatly improved because.
24VDC power supply is backed up for a certtain .
period of time in the eveent of voltage drop or power failure SGE-125-5-1680 00500C-00200F.
Compactness, weight reduction, and long battery life,
realized thanks to the adoption of a lithium-ion battery.
Push-in terminal block adopted for the power input and,
outputt II/F SGE-125-5-1680 00500C-00200F.
Shutdown in conjunction with the industrial,
purpose computer (IPC) or controller realized,
by the USB/RS-232C/I/O port installed in the UPS.
SGE-125-5-1680 00500C-00200F Operation manual/Instructions/Model selection sample download link: