Sensing method: Retroreflective type.
Sensing distance: 200 mm.
Output type: NPN output.
Output configuration: Light-ON.
Photomicrosensor with light,
modulation for reduced external light,
interference.
Easy adjustment and optical axis monitoring with a light indicator.
Wide operating voltage range: 5 to 24 VDC OMRON SGE-225-2-5000 05000C.
Supports connection with Programmable Controllers (PLCs).
Easy-to-wire connectors assure easy maintenance
SGE-225-2-5000 05000C E32-D11R type: standard type; soft (new standard),
Specialty: M6 screw,
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsInsulation method: Phototriac OMRON SGE-225-2-5000 05000C.
Operation indicator: Yes.
Zero cross function: NO .
Applicable load: 2 A at 100 to 240 VAC.
Input rated voltage: 5 to 24 VDC.
SSR with Plug-in Terminals.
The Same Shape as the G2R-1-S.
Power Relays.
These I/O solid state relays can be mounted in OMRON.
G70A I/O Terminals.
Lineup includes Input Modules for microloads and Output,
Modules for standard loads OMRON SGE-225-2-5000 05000C.
Lineup also includes UL, CSA, and TÜV-certified models,
(-UTU models) . Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-C.
Output: SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output SGE-225-2-5000 05000C.
Through the infrared port can be carried out from the frronnt of the communication SGE-225-2-5000 05000C.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
SGE-225-2-5000 05000C Operation manual/Instructions/Model selection sample download link: