Input type: DC current input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON SH-001-05M.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
SH-001-05M
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON SH-001-05M.
DevSize: 48 x 96mm .
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater OMRON SH-001-05M.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input .
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Type: rectangle.
Screen mode: no segmentation.
Output: SPDT.
Power supply voltage: DC5V.
Contact type: standard load (AC250V, 3A; DC30V, 3A).
Operation: instantaneous action (auto reset).
Operation Department color: White (using yellow and green LED).
In the touch and the ability to protect than OMRON''s previous models have improvedd .
The micro volume design of 23mm is realized SH-001-05M.
Micro design and unique combination of soft sensing.
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous modell bbased on the OMRON to improve the protection SH-001-05M.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient.
SH-001-05M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SH-001-05M&select=5