Size: M12, Shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 34 (50).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor SGE-245-2-1220 02000C.
Problems such as the collision of workpieces are eliminated
SGE-245-2-1220 02000C
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection distance: infrared 1mmmm SGE-245-2-1220 02000C.
Output mode: NPN output. Item: Logic Alarm Cable (2 m) .
Easy-to-use and Compact 10-Channel Logger,
with Internal 4 GB Flash Memory. Name: PID Control Module.
Model: C200H-PID01.
Output: Transistor output (open collector).Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic SGE-245-2-1220 02000C.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) .
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON SGE-245-2-1220 02000C.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller inteernnal relay OMRON SGE-245-2-1220 02000C.
Increased the 3 segment display, which can display the current value / target / operation.
Added PF keys to assign automatic / manual, RUN/
SGE-245-2-1220 02000C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-245-2-1220 02000C&select=5